When you want a straightforward system that’s safe, easy-to-use and won’t cost an arm and a leg, a SafetyOne FS1A safety controller is the answer!
Unlike a multiple safety relay system, which requires cumbersome wiring and take up too much space, or safety PLCs that can be costly and difficult to program, our safety controllers make it easy to consolidate safety circuits. At the same time they meet safety requirements, save space with minimal wiring and cost customers less money.
SafetyOne can replace up to six safety relay modules with no programming. Easily configure by turning on a dip switch to 1 of 24 pre-defined logic circuits and one module can connect with various IDEC safety and non safety components such as Emergency Stop switches, Interlock Switches, pilot lights, sensors and light curtains. With up to 6 dual channel safety inputs, 4 safety outputs and multiple non safety inputs, monitor, blanking and solenoid drive outputs, SafetyOne can simplify your complete safety and logic circuit.
FS1A is UL listed, TUV rated and CE marked, as well as meets IEC 61508 integrity level 3, ISO 13849-1 performance level e and EN954-1 safety category 4.
Choose from 24 built-in safety control logics
The FS1B’s pre-loaded, pre-certified safety control logics suit a wide variety of users and applications. Simply select the logic that best suits your equipment setup and circuit pattern.
There are logic options for equipment with multiple access points, for spaces where robots (cobots) and humans work together, and many more. Use cases and circuit diagrams for all 24 logics are provided in the product catalog.
Make certification and safe operations more straightforward
The FS1B is a solution designed to prioritize safety. Every built-in logic complies with international safety standards and has been certified by a trusted independent body. The circuit logic patterns are compatible with systems up to Safety Category 4 and PLe.
Pre-certification streamlines the overall approval process for your machinery and logic setup. There is no need to seek recertification after circuit pattern design changes.
No programming or software required
Logics can quickly be selected with DIP switches and implemented without programming knowledge. Simply choose a logic number and get started.
You can also pre-test logics with the safety controller’s logic simulator. No need to install software – access the simulator via the link on this page.
Ideal for controlling small-scale systems
Use the FS1B safety controller to monitor up to 6 input devices and up to 4 output devices in a single system. It can be used to control emergency stop switches, light curtains, interlock switches, safety laser scanners, and many other safety input and safety output devices.